Analog accelerometers

Precise and robust: Accelerometers from ASC
We offer you a large selection of capacitive, piezoresistive and piezoelectric accelerometers with outstanding features and analog output signal.

Our capacitive accelerometers detect even smallest linear accelerations and low-frequency dynamic accelerations, with maximum precision. They feature low noise performance (LN series) and a wide frequency response measurement range (MF series). Based on different technologies the analog accelerometers providing high shock resistance, long-term stability and a very broad measurement range (piezoelectric) or are used in high-impact tests (piezoresistive).

asc_icon_arrow_big

Analog accelerometers

Our product filter offers a fast and easy way for you to find the right sensor solution for your application.

Number of sensitive directions
Number of sensitive directions
Additional filter options for analog accelerometers:
Sensor technology
Sensor technology
Output signal
Output signal
Frequency range [Hz]
Frequency range [Hz]
Measurement range [g]
Measurement range [g]
Operating temperature min. [°C]
Operating temperature min. [°C]
Operating temperature max. [°C]
Operating temperature max. [°C]
Protection class
Protection class

Would you like a personal consultation or do you need more information?

Contact our team of engineers! We will be glad to help you – at no charge and no obligation.

E-mail: service[at]asc-sensors.de
Phone +49 8441 786547-0

ASC 3511LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 3521MF

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz

ASC 4111LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 4211LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 4221MF

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz

ASC 4311LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 4315LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 4321MF

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz

ASC 4325MF

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz

You haven't found a suitable sensor?

ASC sensors are manufactured at our Pfaffenhofen location in Germany from the highest quality components and also individually developed according to customer requirements.

Service

Press: Köhler + Partner GmbH

Press

Management

Career

Inquiry: Analog accelerometers

Anzahl Achsen
Anzahl Achsen
Sensortechnologie
Sensortechnologie
Temperatur min - max
Temperatur min - max
Sensorart
Sensorart

ASC 5411LN

Triaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC P101A15

Uniaxial, IEPE
Measurement range: ±50 to ±1000 g
Frequency range (±10 %): 0.3 Hz to 10 kHz
Scale factor: 5 mV/g to 100 mV/g