Analog sensors

Flexible data processing
Analog inertial sensors provide a more detailed range of information than sensors with a digital output signal. They allow the user to utilize the entire spectrum of measurements by data acquisition devices and software. Analog sensors also make the processes of testing and measuring engineers extremely flexible, since they can define the type and scope of data evaluation themselves.

asc_icon_arrow_big

Analog sensors

Our product filter offers a fast and easy way for you to find the right sensor solution for your application.

Sensor type
Sensor type
Number of sensitive directions
Number of sensitive directions
Additional filter options for analog accelerometers:
Sensor technology
Sensor technology
Output signal
Output signal
Frequency range [Hz]
Frequency range [Hz]
Measurement range [g]
Measurement range [g]
Operating temperature min. [°C]
Operating temperature min. [°C]
Operating temperature max. [°C]
Operating temperature max. [°C]
Protection class
Protection class

Would you like a personal consultation or do you need more information?

Contact our team of engineers! We will be glad to help you – at no charge and no obligation.

E-mail: service[at]asc-sensors.de
Phone +49 8441 786547-0

Drehratensensor ASC 271

ASC 271

Uniaxial, Industrial Grade
Measurement range: 75 °/s to 900 °/s
Bias stability: 12 °/h
Angular random walk: 0.2 °/√h

Drehratensensor ASC 273

ASC 273

Triaxial, Industrial Grade
Measurement range: 75 °/s to 900 °/s
Bias stability: 12 °/h
Angular random walk: 0.2 °/√h

Drehratensensor ASC 281

ASC 281

Uniaxial, Tactical Grade
Measurement range: 10 °/s to 400 °/s
Bias stability: <0.1 °/h
Angular random walk: <0.01 °/√h

ASC 283

Triaxial, Tactical Grade
Measurement range: 10 °/s to 400 °/s
Bias stability: <0.1 °/h
Angular random walk: <0.01 °/√h

ASC 3511LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 3521MF

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz

ASC 4111LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 4211LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 4221MF

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz

You haven't found a suitable sensor?

ASC sensors are manufactured at our Pfaffenhofen location in Germany from the highest quality components and also individually developed according to customer requirements.

Service

Press: Köhler + Partner GmbH

Press

Management

Career

Inquiry: Analog sensors

Anzahl Achsen
Anzahl Achsen
Sensortechnologie
Sensortechnologie
Temperatur min - max
Temperatur min - max
Sensorart
Sensorart

ASC 4321MF

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz

ASC OS-125MF-PG

Uniaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz