Analog sensors

Flexible data processing
Analog inertial sensors provide a more detailed range of information than sensors with a digital output signal. They allow the user to utilize the entire spectrum of measurements by data acquisition devices and software. Analog sensors also make the processes of testing and measuring engineers extremely flexible, since they can define the type and scope of data evaluation themselves.

asc_icon_arrow_big

Analog sensors

Our product filter offers a fast and easy way for you to find the right sensor solution for your application.

Sensor type
Sensor type
Sensors according to railway standard EN50155
Sensors according to railway standard EN50155
Number of sensitive directions
Number of sensitive directions
Additional filter options for analog accelerometers:
Sensor technology
Sensor technology
Output signal
Output signal
Frequency range [Hz]
Frequency range [Hz]
Measurement range [g]
Measurement range [g]
Operating temperature min. [°C]
Operating temperature min. [°C]
Operating temperature max. [°C]
Operating temperature max. [°C]
Protection class
Protection class

Would you like a personal consultation or do you need more information?

Contact our team of engineers! We will be glad to help you – at no charge and no obligation.

E-mail: service[at]asc-sensors.de
Phone +49 8441 786547-0

FUTURESES H68C

Triaxial, piezoresistive
Measurement range: ±500 and ±2000 g
Housing (±10 %): DC to 7000 Hz
SAE J211 & SAE J2570

JA-25GA

Uniaxial, Q-MEMS
Measurement range: ±4 g
Temperature range: -40 °C to +175 °C
Stability: Combined K1 and K0: 1.8 mg

JA-40GA

Uniaxial, Q-MEMS
Measurement range: ±2 to ±8 g
Resolution: 1 µg
Temperature range: -20 °C to +70 °C

JA-5 Type III

Uniaxial, Q-MEMS
Measurement range: ±20 g
Temperature range: -54 °C to +96 °C
Stability: K1: 400 ppm | K0: 0.1 mg

JA-50GA

Uniaxial, Q-MEMS
Measurement range: ±20 g
Temperature range: -55 °C to +96 °C
Stability: K1: 1200 ppm | K0: 1.5 mg

JA-5H175

Uniaxial, Q-MEMS
Measurement range: ±4 g
Temperature range: -40 °C to +175 °C
Stability: Combined K1 and K0: 1.8 mg

JA-5H190

Uniaxial, Q-MEMS
Measurement range: ±4 g
Temperature range: -20 °C to +190 °C
Stability: Combined K1 and K0: 1.8 mg

JA-5H200

Uniaxial, Q-MEMS
Measurement range: ±4 g
Temperature range: 0 °C to +200 °C
Stability: Combined K1 and K0: 1.8 mg

JA-5M36

Uniaxial, Q-MEMS
Measurement range: ±4 g
Temperature range: -40 °C to +150 °C
Stability: Combined K1 and K0: 1.8 mg

You haven't found a suitable sensor?

ASC sensors are manufactured at our Pfaffenhofen location in Germany from the highest quality components and also individually developed according to customer requirements.

Service

Press: Köhler + Partner GmbH

Press

Management

Career

Inquiry: Analog sensors

Anzahl Achsen
Anzahl Achsen
Sensortechnologie
Sensortechnologie
Temperatur min - max
Temperatur min - max
Sensorart
Sensorart

ASC 4211LN

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

ASC 5525MF

Triaxial, capacitive
Measurement range: ±2 to ±200 g
Noise density: 10 to 680 µg/√Hz
Frequency range (±5 %): DC to 2900 Hz