ASC CS-1511LN
Biaxial, capacitive
Measurement range: ±2 to ±50 g
Output signal: 4-20 mA
Scale factor: 0.16 mA/g to 4 mA/g
High-precision sensors are the basis for demanding measurement tasks in many applications around the world. That is why we use carefully selected components of very high quality for the production of our accelerometers, gyroscopes tilt sensors and inertial measurement units.
All ASC sensors are developed, manufactured, calibrated and, if desired, customized in Germany. Our engineers adjust them for example with custom cable lengths, connectors and housing versions to achieve the required quality. Together with you, it is also possible to develop a completely new sensor or sensor solution for your application.
Whether analog, digital or smart – we always deliver the optimal sensor solution for your application. ASC’s experienced engineers are glad to provide support in choosing the right sensor or a complete sensor solution.
Our product filter offers a fast and easy way for you to find the right sensor solution for your application.
Contact our team of engineers! We will be glad to help you – at no charge and no obligation.
E-mail: service[at]asc-sensors.de
Phone +49 8441 786547-0

Biaxial, capacitive
Measurement range: ±2 to ±50 g
Output signal: 4-20 mA
Scale factor: 0.16 mA/g to 4 mA/g

Triaxial, capacitive
Measurement range: ±2 to ±50 g
Output signal: 4-20 mA
Scale factor: 0.16 mA/g to 4 mA/g

Uniaxial, capacitive
Measurement range: ±2 to ±50 g
Output signal: 4-20 mA
Scale factor: 0.16 mA/g to 4 mA/g

Uniaxial, industrial grade
Measurement range: 75 °/s to 900 °/s
Bias stability: 12 °/h
Angular random walk: 0.2 °/√h

Triaxial, capacitive
Measurement range: Configurable ±2 to ±40 g
Noise density: 22.5 to 90 µg/√Hz
Output signal: USB, CAN, RS-232

Triaxial, capacitive
Standards: EN 50155
Measurement range: Configurable ±2 to ±8 g or ±10 to ±40 g
Noise density: <1.2 µg/√Hz
Output signal: CAN

Triaxial, capacitive
Measurement range: ±3 and ±5 g
Noise density: <1.2 µg/√Hz
Output signal: USB

Uniaxial, capacitive
Measurement range: ±2 to ±40 g
Output signal: 4-20 mA
Frequency range (±5 %): DC to 630 Hz

Biaxial, capacitive
Measurement range: ±2 to ±40 g
Output signal: 4-20 mA
Frequency range (±5 %): DC to 630 Hz

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz

Uniaxial, capacitive
Measurement range: ±2 to ±400 g
Noise density: 7 to 400 µg/√Hz
Frequency range (±5 %): DC to 2000 Hz
You are currently viewing a placeholder content from Vimeo. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More Information